EndoAngel AI Platform
Technology
State-of-the-art deep learning models optimized for real-time medical image analysis — designed to integrate seamlessly into existing clinical workflows.
100K+
Clinical
Cases
800K+
Annotated
Images
<40ms
Inference
Latency
Full GI
Detection & QC
Gastroscopy · Colonoscopy · EUS
Scope
Compatible
Major brands
supported
Core Technology
AI Architecture
EndoAngel uses state-of-the-art deep learning models optimized for real-time medical image analysis, trained on large-scale multi-center endoscopy datasets with expert-validated ground truth labels.
🧠
Deep Learning Framework
- Convolutional Neural Networks (CNN)
- Multi-task: detection, segmentation & classification
- Federated learning for continuous improvement
- Trained on 100,000+ annotated images
⚡
Real-time Processing
- Inference latency <40ms per frame
- Hardware-accelerated GPU processing
- Zero impact on endoscopy workflow
- Supports 1080p input resolution
📈
Training Data Quality
- Multi-center data from leading hospitals
- Expert-validated ground truth labels
- Diverse patient populations
- Multiple equipment brands and settings
Upper GI AI — Gastroscopy Interface
Colonoscopy AI — Detection Interface

Procedure Time Recording: Records the inspection time and the esophageal review time during the procedure.
Real-Time Operation Scoring: Monitors blind spots and automatically scores the physician’s operation according to standardization guidelines.
Blind Spot Monitoring: Indicates the number of anatomical sites already covered and those yet to be examined.
Early Cancer Recognition: Intelligently identifies high-risk lesions, highlighted with a red bounding box and voice reminder.
Model Illumination: Real-time reminder of all 28 gastric anatomical sites with illumination of the corresponding model area.
Automatic Image Collection: Representative images of sites and lesions are automatically captured and saved during the procedure.
EndoAngel Lower GI Quality Control
Colonoscopy AI — Withdrawal Interface

Procedure Time Recording: Records the intubation time and withdrawal time during the endoscopic procedure.
Real-Time Bowel Preparation Scoring: Intestinal preparation scores (eBBPS) are calculated and displayed in real time.
Withdrawal Speed Monitoring: Monitors withdrawal speed in real time and displays it on a panel to alert the endoscopist.
Adenoma / Polyp Recognition: Intelligently identifies high-risk lesions in real time, highlighted with a red bounding box.
Ileocecal Valve Reminder: Automatically identifies arrival at the ileocecal valve and illuminates the intestinal model accordingly.
Automatic Image Collection: Representative images of sites and lesions are automatically captured and saved during the procedure.
EndoAngel Upper GI Quality Control Indicators
| Quality Control Index | Corresponding EndoAngel Function |
|---|---|
| Sufficient esophageal endoscopy time (>2 min) | Automatic esophageal timing |
| Adequate inspection time for stomach and duodenum (>5 min) | Automatic gastric cavity timing |
| Recording and feedback of inspection time (>90%) | Automatic time recording |
| Systematic observation of entire esophagus and stomach (intragastric views >22 images) | Blind spot monitoring (26 zones) and standardization of endoscopist operations |
| Comprehensive and accurate acquisition of endoscopic images | Automatic image capture |
| Training endoscopists to identify suspicious lesions under white light | Real-time assistance under white light to indicate suspicious lesions |
| White-light endoscopy combined with image-enhanced endoscopy (e.g., NBI) for suspicious lesions | Real-time assistance under NBI to indicate suspicious lesions |
EndoAngel Lower GI Quality Control Indicators
| Quality Control Index | Corresponding EndoAngel Function |
|---|---|
| Cecal intubation rate: screened patients ≥95% / all patients ≥90% | Real-time withdrawal speed monitoring |
| Withdrawal process must be slow; withdrawal time in negative colonoscopy (≥6 min) | Real-time withdrawal speed monitoring |
| Recording of withdrawal time (>90%) | Automatic recording and timing |
| Polyp detection rate (≥40%) | Real-time assistance for polyp recognition |
| Adenoma detection rate (>25%) | Real-time assistance for polyp type identification and adenoma diagnosis |
| Pedunculated polyps and serrated polyps <2 cm not suitable for surgical resection should attempt endoscopic resection first | Real-time identification of polyp types |
| Bowel preparation assessment (Boston standard) | Automatic bowel preparation scoring |
Blind Spot Monitoring During Upper GI Endoscopy (26 Zones)

Withdrawal Speed Monitoring

Integration Design
Integration Design
EndoAngel connects via HDMI pass-through — no modification to existing equipment, no IT integration required. Works with Olympus, Fujifilm and Pentax systems.
Seamless Workflow
- HDMI pass-through: plug and play installation
- No modification to existing endoscopy equipment
- Compatible with Olympus, Fujifilm, Pentax
- Works with existing monitor or secondary screen
Deployment Options
- Standalone bedside unit
- Department-level server (multi-room support)
- Cloud-connected for remote updates and analytics
Technical Specifications
| Parameter | Value |
|---|---|
| Inference latency | <40ms per frame |
| Input resolution | 1080p supported |
| Compatible scopes | Olympus, Fujifilm, Pentax |
| Connection | HDMI pass-through |
| AI model updates | OTA via secure connection |
| Certifications | NMPA (China) · CE Mark (EU) |
| Data processing | 100% local — no external transmission |
| Compliance | GDPR · local data protection regulations |
Data Security
All image processing is performed locally at the hospital. No patient data is transmitted externally at any time.
- All processing performed locally at the hospital
- No patient data transmitted externally
- DICOM-compatible data handling
- GDPR and local data protection compliant
Continuous Improvement
EndoAngel is continuously improving through secure OTA updates and ongoing clinical validation studies with partner hospitals.
- Regular AI model updates via secure OTA
- Performance analytics dashboard
- Ongoing clinical validation studies
- Feedback loop with clinical partners
See the Technology in Action
Schedule a live demonstration at your facility — no commitment required.